Productos ¿Quiénes Somos? Boletín de Noticias de ASTM Contacto Ligas Externas Empresas
 

barra

 
Floating Floor System

 

 

System features

• Approved as A60 rated deck construction.
• Effective structural noise damping and sound insulation.
• High load bearing capacity with 2 mm steel surface.
• Easy and fast installation - handy sized units, fully insulated.
• Units jointed by tack welding - no additional fastening.

System description

TNF system FS floating floor is designed for universal applications on ships and offshore installations.

The TNF floor units FS7 and FS5 consists of a specially developed Rockwool insulation material surfaced by a 2 mm thick steel plate.

This special insulation adds significantly to the strength of the surface (see the graphs).

System application

The TNF floating floor unit FS7 has been developed to meet the latest requirements for:

• A60 Fire insulation (A60 deck construction) and
• High noise reduction (low noise level)

The figure below shows the airborne sound insulation of

1) a 6 mm steel deck
2) the same deck with the FS7 floor unit installed.


The floating floor also serves the purpose of absorbing vibrations and sound that spread through the steel deck.

Product specifications

Installation

Levelling of steel deck

To ensure a flat surface the steel deck may require levelling before laying the TNF floor units.

Layout of TNF floor units

The units are laid in staggered rows. The layout of the units should start at a corner.

Due to the characteristics of the mineral wool, minor inequalities of the deck surface may be taken up by the floor units.

Cutting of TNF floor units

The units are easily cut by an angle grinder or similar.

Connecting TNF floor units

The units are tack-welded together on all edges per every 300 mm.


Finish

The joints between the units should be sealed.

Uniform load test

The general uniform load on the floors in an accomodation of a ship can be estimated as follows:

Corridors:
2.5 kN/m2 (52 lbs/sq.ft.)

Cabins:
1.5 kN/m2 (31 lbs/sq.ft.)

Public Areas:
2.5 kN/m2 (52 lbs/sq.ft.)

The max. uniform load (static and dynamic) on a FS7 floor should not exceed: 10 kN/m2 (52 lbs/sq.ft.)

Point load tests

This test simulates the impact from heavy furniture, etc. - on the floor in general.

The max. recommended load is 2.0 kN (438 lbs.) - at the edge of the floor.
Line load test

Walls inclusive items fixed to the walls, doors etc. give a line load impact on the floor.

The FS7 floor is recommended for loads up to: 3 kN/m (208 lbs), witch is sufficient for ordinary use aboard vessels.